HBOT Chambers
Hytech-Pommec designs and manufactures multi-place hyperbaric oxygen therapy (HBOT) chambers for clinical and hospital environments, engineered for patient comfort, safety and regulatory compliance.
2 of our chamber models are shown below — contact us for the full range, including Man Lock Chambers, custom yacht installations and containerised life support systems.
| Model | Configuration | Treatment capacity | Certification status |
|---|---|---|---|
| HBO Triple Lock Medical Chamber | Triple-lock (Entrance Lock, Main Chamber 1, Main Chamber 2) | Up to 24 patients + attendants simultaneously | MDR 2017/745 compliant; CE marked |
| HYOT 2200-8-2 RD | Twin-lock, Ø 2200 mm (Ø 2700 mm also possible) | 8 seated in main chamber + 2 in entrance lock | MDR certification ongoing with Kiwa Assurance B.V. |
HBO Triple Lock Medical Chamber
Multi-place hyperbaric oxygen chamber for safe, comfortable and efficient clinical HBOT treatments.
Contact us about this modelThe Triple Lock hyperbaric oxygen chamber is a cylindrical multi-place HBOT system designed for professional medical environments. Its three-compartment configuration consists of an Entrance Lock, Main Chamber 1 and Main Chamber 2, with capacity for simultaneous treatment of up to 24 patients plus attendants.
The chamber combines clinical treatment capability with advanced monitoring, redundant control systems and a flexible interior configuration for routine and intensive hyperbaric operations.
Flexible Clinical Treatment: Rectangular doors provide access for wheelchairs and stretchers, while the modular interior allows operators to switch quickly between seating and stretcher configurations. Luxury fire-retardant seating includes adjustable backrests, foldable armrests and integrated leg and foot support.
The Built-In Breathing System supports air at 21% Oâ‚‚, 100% oxygen and optional Heliox. Operators can manage simultaneous gas switching per chamber, while masks and hood tents can operate at the same time.
An overboard exhaust system directs exhaled gas outside the building. Safety regulators help prevent excessive negative pressure, while fully oxygen-compatible materials and rigid oxygen piping support safe operation.
Advanced Control and Monitoring: A central ergonomic control console with PLC and HMI touchscreen gives operators access to real-time pressure profiles and chamber parameter visualization. The system supports fully automatic, semi-automatic and fully manual operation.
Computer-controlled pressurization and depressurization operate alongside manual pressure control valves, independent pressure gauges for each compartment and emergency exhaust valves for rapid depressurization. A secondary pressure control system also supports full manual operation when required.
Continuous Oâ‚‚ and COâ‚‚ monitoring helps maintain controlled chamber conditions. Automatic flushing with adjustable rates supports atmosphere management, while the system automatically shuts off oxygen if Oâ‚‚ levels exceed 23%. Visual and acoustic alarms provide additional warning during unsafe conditions.
The system also includes an operator presence safety check every three minutes, with automatic depressurization if the operator fails to respond.
Patient Comfort and Observation: The chamber environment is designed to support patient comfort throughout extended treatment sessions. Individual reading lights are fitted at each seat, while LED chamber lighting offers dimming and low heat emission.
Heating and cooling are controlled through heat exchangers in each main chamber, a chiller system and a hot water heating system. Controlled temperature fluctuation limits help maintain a stable internal environment, while silenced climate-control housings and low-noise gas inlet and exhaust systems reduce disturbance.
Large viewports improve visibility between patients and operators. A nine-camera observation system provides additional visual monitoring throughout the chamber.
Internal information panels display time, remaining session time, pressure, temperature and mask on/off status, giving occupants clear information during treatment.
Communication and System Integration: Two-way communication operates in all compartments through an integrated intercom, speakers and microphones. A fully independent battery-powered backup communication system provides additional redundancy.
The chamber also includes an entertainment system with USB and SD support. Medical-grade penetrators provide dedicated interfaces for gas, power and monitoring equipment.
Integrated Safety and Redundancy: The chamber incorporates a certified hyperbaric water fire suppression system with sprinklers and portable extinguishers inside the chamber. The fire system supports redundant activation from both inside the chamber and the control console.
During a fire event, the system automatically switches from oxygen to air. The fire safety system complies with EN 16081.
Primary low-pressure and secondary high-pressure air supply systems provide further operational redundancy. Automatic emergency switchover allows the backup air system to take over when required, while the available air reserves support extended emergency operation. Breathing air quality complies with EN 12021.
Data Logging and Traceability: The system supports full treatment session logging for pressure profiles, gas concentrations, temperature, humidity and session timing. Operators can review this information through graphical and numerical displays.
All compartments can be monitored simultaneously, giving the control team a complete overview of chamber conditions and treatment progress.
Compliance and Certification: The system is designed to comply with MDR 2017/745 for medical devices, PED 2014/68/EU for pressure equipment, EN 14931 for PVHO requirements, EN 16081 for fire safety and EN 12021 for breathing air quality.
Viewports comply with ASME-PVHO-1. The chamber carries CE marking for the EU and is supported by an ISO 13485 certified quality management system.
- Chamber type
- Cylindrical multi-place hyperbaric oxygen treatment (HBOT) chamber
- Configuration
- Triple-lock
- Compartments
- Entrance Lock (EL), Main Chamber 1 (MC1), Main Chamber 2 (MC2)
- Treatment capacity
- Up to 24 patients + attendants simultaneously
- Doors
- Rectangular, allowing access for wheelchairs and stretchers
- Interior
- Modular, allowing quick change between seats and stretchers
- Seating
- Luxury, fire-retardant
- Seat backrests
- Adjustable
- Seat armrests
- Foldable
- Leg/foot support
- Included
- Reading lights
- Individual per seat
- Climate control
- Heating & cooling
- Gas inlet/exhaust system
- Low-noise with silencers
- Viewports
- Large
- Breathing system
- Built-In Breathing System (BIBS)
- BIBS air
- 21% Oâ‚‚
- BIBS oxygen
- 100% Oxygen
- Heliox
- Optional
- Gas switching
- Simultaneous gas switching per chamber
- Exhaust system
- Overboard exhaust; exhaled gas expelled outside building
- Safety regulators
- Prevent excessive negative pressure
- Breathing interfaces
- Masks and hood tents usable simultaneously
- Oxygen system materials
- Fully oxygen-compatible materials
- Oxygen system piping
- Rigid piping
- Gas inlet/exhaust valves
- Computer-controlled
- Redundant gas control
- Manual
- Chamber flushing
- Automatic with adjustable rates
- Oxygen monitoring
- Continuous
- COâ‚‚ monitoring
- Continuous
- Automatic oxygen shut-off
- If Oâ‚‚ exceeds 23%
- Alarms
- Visual and acoustic
- Camera system
- 9 cameras total
- Lighting
- LED with dimming and low heat emission
- Penetrators
- Medical-grade for gas, power and monitoring
- Internal information display
- Time & remaining session time, pressure, temperature, mask on/off status
- Communication
- Two-way communication in all compartments
- Communication equipment
- Intercom, speakers and microphones
- Entertainment system
- USB / SD
- Backup communication
- Fully independent, battery-powered
- Control console
- Central ergonomic control console
- Control system
- PLC + HMI touchscreen
- Pressure display
- Real-time pressure profiles
- Parameter display
- Chamber parameter visualization
- Operation modes
- Fully automatic, semi-automatic, fully manual override
- Operator presence check
- Every 3 minutes
- Operator non-response action
- Automatic depressurization
- Pressurization/depressurization
- Computer-controlled
- Backup pressure control
- Manual pressure control valves
- Pressure gauges
- Independent per compartment
- Emergency exhaust
- Emergency exhaust valves for rapid depressurization
- Secondary pressure control
- Full manual operation
- Main chamber heat exchangers
- Heat exchangers in each main chamber
- Cooling
- Chiller system
- Heating
- Hot water system
- Temperature control
- Controlled temperature fluctuation limits
- Climate-control housings
- Silenced
- Primary air supply
- Low-pressure air supply system
- Secondary air supply
- High-pressure backup air system
- Breathing air quality
- EN 12021
- Emergency air switchover
- Automatic
- Emergency air reserves
- Sufficient for extended emergency operation
- Fire suppression
- Certified hyperbaric water fire suppression system
- Fire-event gas switching
- Automatic switch from oxygen to air
- Internal fire equipment
- Sprinklers and portable extinguishers
- Fire safety standard
- EN 16081
- Fire-system activation
- Redundant activation inside chamber + control console
- Treatment logging
- Full treatment session logging
- Logged pressure data
- Pressure profiles
- Logged gas data
- Gas concentrations
- Logged environmental data
- Temperature & humidity
- Logged timing data
- Session timing
- Data display
- Graphical and numerical
- Monitoring
- Simultaneous monitoring of all compartments
- Medical device compliance
- MDR 2017/745
- Pressure equipment compliance
- PED 2014/68/EU
- PVHO standard
- EN 14931
- Fire safety compliance
- EN 16081
- Breathing air compliance
- EN 12021
- Viewport standard
- ASME-PVHO-1
- CE marking
- EU
- Quality management system
- ISO 13485 certified
Chamber Design & Capacity
- Cylindrical multi-place hyperbaric oxygen treatment (HBOT) chamber
- Triple-lock configuration (Entrance Lock, Main Chamber 1, Main Chamber 2)
- Simultaneous treatment of up to 24 patients plus attendants
- Rectangular doors allowing access for wheelchairs and stretchers
- Modular interior allowing quick change between seats and stretchers
Patient Comfort & Usability
- Luxury, fire-retardant seating with adjustable backrests, foldable armrests, leg/foot support
- Individual reading lights per seat
- Climate-controlled environment with heating and cooling
- Low-noise gas inlet/exhaust system with silencers
- Large viewports for patient visibility and reassurance
Therapeutic Breathing System
- Built-In Breathing System (BIBS) for air (21% Oâ‚‚), 100% oxygen, optional Heliox
- Simultaneous gas switching per chamber
- Overboard exhaust system, exhaled gas expelled outside the building
- Safety regulators preventing excessive negative pressure
- Masks and hood tents can be used simultaneously
- Fully oxygen-compatible materials and rigid piping for fire safety
Gas Control & Safety Systems
- Computer-controlled gas inlet and exhaust valves
- Manual redundant gas control system
- Automatic chamber flushing with adjustable rates
- Continuous monitoring of oxygen and COâ‚‚ concentration
- Automatic oxygen shut-off if Oâ‚‚ exceeds 23%
- Visual and acoustic alarms for unsafe conditions
Electrical & Monitoring Systems
- Full camera observation system with 9 cameras
- LED lighting with dimming and low heat emission
- Medical-grade penetrators for gas, power and monitoring
- Internal information panels showing time/remaining session time, pressure, temperature, mask on/off status
Communication & Entertainment
- Two-way communication in all compartments
- Intercom, speakers and microphones
- Entertainment system with USB/SD
- Fully independent battery-powered backup communication system
Control Console & Automation
- Central ergonomic control console with PLC + HMI touchscreen, real-time pressure profiles, chamber parameter visualization
- Three operation modes: fully automatic, semi-automatic, fully manual override
- Operator presence safety check every 3 minutes
- Automatic depressurization if the operator fails to respond
Pressure Control & Redundancy
- Computer-controlled pressurization and depressurization
- Manual pressure control valves as backup
- Independent pressure gauges per compartment
- Emergency exhaust valves for rapid depressurization
- Secondary pressure control system for full manual operation
Climate Control
- Heat exchangers in each main chamber
- Chiller system for cooling
- Hot water system for heating
- Controlled temperature fluctuation limits
- Silenced housings for patient comfort
Air Supply & Machinery
- Primary low-pressure air supply system
- Secondary high-pressure backup air system
- Compliance with EN 12021 breathing air quality
- Automatic switchover in emergency conditions
- Sufficient air reserves for extended emergency operation
Fire Safety
- Certified hyperbaric water fire suppression system
- Automatic switch from oxygen to air during a fire event
- Sprinklers and portable extinguishers inside the chamber
- Certified to EN 16081
- Redundant activation from inside the chamber and control console
Data Logging & Traceability
- Full treatment session logging (pressure profiles, gas concentrations, temperature/humidity, session timing)
- Graphical and numerical data display
- Simultaneous monitoring of all compartments
Compliance & Certification
- Designed to comply with MDR 2017/745, PED 2014/68/EU, EN 14931 (PVHO), EN 16081 (fire safety), EN 12021 (breathing air), ASME-PVHO-1 (viewports)
- CE marking (EU)
- ISO 13485 certified quality management system
HYOT 2200-8-2 RD (Ø 2200 mm)
Medical-grade HBOT chamber engineered for safety, comfort and performance for up to 8 patients.
Contact us about this modelThe HYOT 2200mm – 8 – 2 is a twin lock medical-class hyperbaric oxygen therapy chamber designed for clinical and hospital environments. Its 2200 mm diameter pressure vessel provides a spacious treatment environment while supporting reliable and efficient operation. 2700 mm diameter is also possible.
High-Capacity Clinical Configuration: The main treatment compartment accommodates up to 8 patients, while the separate 2-seat entrance lock allows controlled patient transfer without interrupting ongoing treatments. Rectangular doors improve accessibility and support practical patient movement.
Integrated Treatment and Safety Systems: The chamber includes BIBS connections for oxygen delivery and incorporates systems for pressurization, monitoring, communication and emergency response.
Its construction supports long-term durability, reliability and regulatory compliance, making the HYOT 2200mm – 8 – 2 suitable for healthcare facilities requiring a high-capacity HBOT solution.
- Model
- HYOT 2200-8-2 RD (Ø 2200 mm) twin lock
- Pressure Vessel Diameter
- 2200 mm (also 2700 mm possible)
- Main Chamber Capacity
- 8 seated patients (also possible 4-12-16-20, seats can be taken in and out)
- Entrance Lock Capacity
- 2 seated patients
- Chamber Type
- Multiplace Hyperbaric Oxygen Therapy (HBOT) Chamber
- Certification
- Application for MDR certification ongoing with EU notified Body, Kiwa Assurance B.V.
- Compliance
- Meets all applicable European pressure vessel directives and safety standards
- Operating Pressure
- Typically up to 2.5–6.0 ATA (customizable upon request)
- Breathing System
- Integrated BIBS (Built-In Breathing System)
- Control System
- Automated and manual control options
- Monitoring
- Continuous internal and external pressure monitoring
- Communication System
- Internal patient-to-operator communication system
- Safety Systems
- Pressure relief valves, emergency depressurization system, fire safety systems
- Access
- Entry lock for safe transfer during operation; rectangular door design for improved accessibility
- Seating Configuration
- Ergonomic, medical-grade seating
- Viewing Ports
- Multiple acrylic view ports for visibility and patient comfort
- Lighting
- Internal LED lighting system
- Materials
- High-grade steel pressure vessel with medical-grade interior finishing
- High Patient Capacity
- Accommodates up to 8 patients in the main chamber, making it ideal for clinics with high patient throughput.
- Dual-Lock System for Continuous Operation
- The 2-person entrance lock allows patient transfer without interrupting ongoing treatments, increasing operational efficiency.
- Advanced Safety Design
- Engineered to meet all European pressure vessel and safety requirements, with multiple redundant safety systems.
- Integrated BIBS System
- Equipped with Built-In Breathing System connections to ensure safe and controlled oxygen delivery during therapy.
- User-Friendly Operation
- Intuitive control systems with both automated and manual operation modes for flexibility and ease of use.
- Enhanced Patient Comfort
- Spacious 2200mm diameter chamber, ergonomic seating, lighting, and viewing ports create a comfortable treatment environment.
- Reliable Communication Systems
- Continuous communication between operator and patients ensures safety and reassurance throughout treatment sessions.
- Customizable Configuration
- System can be adapted to specific client or facility requirements.
- Built for Durability and Longevity
- Manufactured using high-quality materials and engineering standards for long-term, reliable performance.